Magnetic floating level meter secondary instrumentLHCF2/B Type
An overview of the:
??Secondary instrument is the signal sampling tube 4 ~ 20mA signal processing into the relevant liquid level indication.The 4-channel secondary instrument is used to process 4 ~ 20mA signals of the signal sampling tube into relevant liquid level indication.The meter has 4 alarm outputs and passive contacts (220V/100mA), which can be set online and remembered automatically.
??Water level indication setting:Precast maximum water level range±3000mm。
??Sampling range:Sampling range of sampling tube6000mm。
??Sampling accuracy:10mm
??Self-checking function:Secondary instrument element faults can be shown (mainly for factory commissioning).?